ABB 10DX3111ADD17P1A2BK24321ries 10DX3111ADD17P1A2BK24321 DN80 (3-inch) Remote Mount Electromagnetic Flow...
Core Function This magnetic flowmeter primary element relies on Faraday’s electromagnetic induction to measure volumetric flow of conductive industrial liquids without internal obstructions. It pairs with a remote 50SD1000 signal converter to output linear 4–20mA analog signals plus HART digital data for DCS/PLC/SCADA closed-loop flow regulation, batch totalization, and process monitoring. The full model code defines DN80 size, PTFE corrosion-resistant liner, 316 stainless steel electrodes, IP67 ingress protection, ANSI Class 150 flanges, and factory calibration batch BK24321 for chemical, wastewater, pulp & paper, and petrochemical liquid pipelineseero. It acts as a critical spare flow measurement primary element for plants requiring remote converter installation away from hot, corrosive

Product Description
Core Function This magnetic flowmeter primary element relies on Faraday’s electromagnetic induction to measure volumetric flow of conductive industrial liquids without internal obstructions. It pairs with a remote 50SD1000 signal converter to output linear 4–20mA analog signals plus HART digital data for DCS/PLC/SCADA closed-loop flow regulation, batch totalization, and process monitoring. The full model code defines DN80 size, PTFE corrosion-resistant liner, 316 stainless steel electrodes, IP67 ingress protection, ANSI Class 150 flanges, and factory calibration batch BK24321 for chemical, wastewater, pulp & paper, and petrochemical liquid pipelineseero. It acts as a critical spare flow measurement primary element for plants requiring remote converter installation away from hot, corrosive
Technical Specifications
| Brand | ABB |
|---|---|
| Model | 10DX3111ADD17P1A2BK24321 |
| Category | Industrial Automation |
| Flow Turndown Ratio 100 | 1 wide rangeability |
| Flange-to-flange lay length | 320 mm (12.60 in) |
| Outer body diameter | 165 mm (6.50 in) |
| Coil housing width | 210 mm (8.27 in) |
| Electrode pin corrosion | Moisture ingress in junction box creates high electrode resistance, loss of flow signal to remote converter |
| HART communication dropout | Damaged shielded signal cable or water intrusion in terminal junction box |
| Calibration drift | Long-term high-temperature fluid exposure erases factory BK24321 calibrated linearity |
| 生成PPT | ABB 10DX3111ADD17P1A2BK24321技术档案 |
| Origin | Germany / Original |
| Condition | New Original Factory Sealed |
| Warranty | 12 Months |