ABB 3BHB006715R0217Full Official Part Name: ABB SYNCHROTACT 5 SYN5202A-Z V217 Dual Isolated Chan...

Full Official Part Name: ABB SYNCHROTACT 5 SYN5202A-Z V217 Dual Isolated Channel Automatic Generator Synchronization Controller, Order Code: 3BHB006715R0217 Core Function: Safety-grade dual-channel redundant synchronizer designed for critical power generation assets. Two fully galvanically isolated measurement channels independently sample generator and grid 3-phase voltage, frequency, slip speed and phase angle. It automatically outputs governor speed and excitation trim signals to align electrical parameters; breaker closing interlock only activates when both redundant channels confirm valid sync thresholds, eliminating single-point failure risks. Equipped with dead-bus black-start logic, reverse-power, overvoltage/undervoltage, out-of-phase blocking protection, 10,000 timestamped event

3BHB006715R0217
ABB

Product Description

Full Official Part Name: ABB SYNCHROTACT 5 SYN5202A-Z V217 Dual Isolated Channel Automatic Generator Synchronization Controller, Order Code: 3BHB006715R0217 Core Function: Safety-grade dual-channel redundant synchronizer designed for critical power generation assets. Two fully galvanically isolated measurement channels independently sample generator and grid 3-phase voltage, frequency, slip speed and phase angle. It automatically outputs governor speed and excitation trim signals to align electrical parameters; breaker closing interlock only activates when both redundant channels confirm valid sync thresholds, eliminating single-point failure risks. Equipped with dead-bus black-start logic, reverse-power, overvoltage/undervoltage, out-of-phase blocking protection, 10,000 timestamped event

Technical Specifications

Brand ABB
Model 3BHB006715R0217
Category Uncategorized
Full Official Part NameABB SYNCHROTACT 5 SYN5202A-Z V217 Dual Isolated Channel Automatic Generator Synchronization Controller, Order Code: 3BHB006715R0217
Core FunctionSafety-grade dual-channel redundant synchronizer designed for critical power generation assets. Two fully galvanically isolated measurement channels independently sample generator and grid 3-phase voltage, frequency, slip speed and phase angle. It automatically outputs governor speed and excitation trim signals to align electrical parameters; breaker closing interlock only activates when both redundant channels confirm valid sync thresholds, eliminating single-point failure risks. Equipped with dead-bus black-start logic, reverse-power, overvoltage/undervoltage, out-of-phase blocking protection, 10,000 timestamped event logs, Modbus RTU and IRIG-B time sync for SCADA/DCS integration. Certified IEC 61508 SIL2 for thermal power plants, large hydro units and industrial cogeneration microgridseero.
Front panel full viewSilver panel-mount enclosure, ABB logo, SYNCHROTACT 5 marking, backlit LCD, status LEDs, 6 navigation parameter buttons
Series size comparisonSYN5202 unit alongside smaller DIN rail SYN5100/SYN5200 modules
Front faceplateEmbossed ABB logo, printed SYNCHROTACT 5 identifier, multi-line backlit LCD, red/green/yellow fault/status LEDs, six tactile navigation buttons with parameter lock password protection
Rear wiring compartmentSegmented green spring-cage terminal blocks separating Channel 1 and Channel 2 voltage sensing circuits; dedicated terminals for auxiliary power, relay digital I/O, RS485 serial bus and IRIG-B DB9 time sync connector; integrated braided EMC ground strap for noise suppression
Dual-channel measurement mismatch alarmDegraded sampling resistors or loose potential transformer wiring, triggering sync abort lockout to prevent unsafe paralleling
Modbus/IRIG-B communication dropoutCorroded rear terminal pins or damaged onboard communication transceiver IC, cutting real-time synchronizer status to plant SCADA
Thermal over-temperature shutdownCabinet ventilation blockage or dust buildup activating safety thermal cutout protection
Stuck relay output contactsMechanical wear on breaker-close command digital output relays, unable to send closing signals to generator switchgear
Flash memory parameter corruptionVoltage surge damage to onboard storage chip, resetting all synchronization calibration settings to factory defaults
Channel isolation leakageDamaged PCB isolation barrier causing crosstalk between dual measurement channels, invalidating SIL2 redundant safety function
MountingDIN rail
Redundancydual-channel redundant
Redundancy 2Dual Redundant
Origin Germany / Original
Condition New Original Factory Sealed